Page #94 background image
2
.
DIGITAL
OPERATOR
(JVOP-114)
(Cont
1
d)
2
.7
.2
Monitoring
of
Fault
Contents
-
If
a
fault
occurs,
the
fault
contents are
displayed
with
priority
over
other
display
items
.
Depress
the
aT
key
or
turn
on
the
fault
reset
input
signal
to
reset
the
fault
.
-
Since
the
latest
fault
content
data
are
stored
in
the
inverter,
even
if
the
power
supply
is
turned
off,
they
can
be
monitored
after
the
power
supply
is
turned
on
again
.
,
(1)
Checking
fault
contents
The
latest
data
are
stored
in
the
constant
(No
.48)
.
(except
UV)
(2)
Clearing
fault
contents
The
contents
are
cleared
by
setting
"6"
to the
constant
(No
.00)
.
Or
they
are
also
cleared
by
constant
initialization
.
[Set
constant
(No
.00)
=
8
or
9
.]
At
this
time,
other
constants
are
changed
to
the
factory
setting
values
.
Therefore,
record
all
of
the
constant data
before
initializing
constant
.
(3)
Faults
to
be
stored
OC
(overcurrent),
OV
(overvoltage),
OH
(cooling
fin
overheat),
OL
1
(motor
overload),
OL2
(inverter
overload),
OL3
(overtorque
detection),
EF4,
EF5
(external
fault),
CPF05
(AD
converter
fault)
.
For
details,
refer
to
Table
1
.8
"Fault
Display
and
Contents"
on page 47
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed-606PC3 and is the answer not in the manual?

YASKAWA Varispeed-606PC3 Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed-606PC3
CategoryInverter
LanguageEnglish

Related product manuals