206
096 0160 Overtorque Detection Func-
tion Selection 1
0 to 4 - 0 No 74
097 0161 Overtorque/Undertorque De-
tection Function Selection 2
0, 1 - 0 No 75
098 0162 Overtorque Detection Level 30% to 200% 1% 160% No 75
099 0163 Overtorque Detection Time 0.1 to 10.0 s 0.1 s 0.1 s No 75
100 0164 Hold Output Frequency Sav-
ing
Selection
0, 1 - 0 No 94
101 0165 Speed Search Deceleration
Time
0.1 to 10.0 s 0.1 s 2.0 s No 78
102 0166 Speed Search Operation Lev-
el
0 % to 200 % 1 % 150 % No 78
103 0167 Torque Compensation Gain 0.0 to 2.5 0.1 1.0 Yes 59
104 0168 Torque Compensation Time
Constant
0.0 to 25.5 s 0.1 s (Note 6) No 59
105 0169 Torque Compensation Iron
Loss
0.0 to 6550 0.01 W (less
than 1000
W)/1 W
(1000 W or
more)
(Note 3) No 59
106 016A Motor Rated Slip 0.0 to 20.0 Hz 0.1 Hz (Note 3) Yes 61
107 016B Motor Line-to-neutral Resis-
tance
0.000 to 65.50
0.001 W
(less than 10
W)/0.01 W
(10 W or
more)
(Note 3) No 61
108 016C Motor Leakage Inductance 0.00 to
655.0 mH
0.01 mH
(less than
100 mH)/0.1
mH (100 mH
or more)
(Note 3) No 62
109 016D Torque Compensation Volt-
age Limiter
0% to 250% 1% 150% No -
110 016E Motor No-load Current 0% to 99% 1% (Note 3) No 60
111 016F Slip Compensation Gain 0.0 to 2.5 0.1 (Note 6) Yes 106
112 0170 Slip Compensation Time Con-
stant
0.0 to 25.5 s 0.1 s (Note 6) No 106
113 0171 Slip Compensation During Re-
generative Operation
0, 1 - 0 No -
No. Register
No. for
Trans-
mission
Name Setting Range Setting Unit Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page

Table of Contents