9. Specifications
207
Fourth Functions (Constants n120 to n179)
114 0172 Number of Transmission Cy-
cle Error Detection (For SI-T/
V7)
2 to 10 - 2 No 159
115 0173 Stall Prevention Above Base
Speed During Run
0, 1 - 0 No 104
116 0174 Acceleration/deceleration
Time during Stall Prevention
0, 1 - 0 No 105
117 0175 Undertorque Detection Func-
tion Selection 1
0 to 4 - 0 No 154
118 0176 Undertorque Detection Level 0% to 200% 1% 10% No 154
119 0177 Undertorque Detection Time 0.1 to 10.0 s 0.1 s 0.1 s No 154
No. Register
No. for
Trans-
mission
Name Setting Range Setting Unit Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page
120 0178 Frequency Reference 9 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz Yes 67
121 0179 Frequency Reference 10 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz Yes 67
122 017A Frequency Reference 11 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz Yes 67
123 017B Frequency Reference 12 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz Yes 67
124 017C Frequency Reference 13 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz Yes 67
125 017D Frequency Reference 14 0.00 to 400.0
Hz
0.01 Hz
(less than
100 Hz)/0.1
Hz (100 Hz
or more)
0.00 Hz Yes 67
No. Register
No. for
Trans-
mission
Name Setting Range Setting Unit Factory
Setting
Change
during
Opera-
tion
User
Set-
ting
Ref.
Page

Table of Contents