BROADSOFT PARTNER CONFIGURATION GUIDE YEALINK W60B IP DECT PHONE 20-BD5561-00
©
2018 BROADSOFT INC. PAGE 19 OF 117
Step Command Purpose
System Configuration Items y0000000000<xx>.cfg
Step 4
Set Register Expire Timer.
account.1.expires = 3600
Set the registration period.
Step 5
Enable reliable response.
account.1.100rel_enable = 1
Reliable provisional response
(PRACK) should be enabled.
Step 6
Enable Session Timer.
account.1.session_timer.enable = 1
account.1.session_timer.expires =
300
account.1.session_timer.refresher
= 1
Set the W60B IP DECT PHONE to
enable Session Timer.
Session Refresher:
0 = uac
1 = uas
Step 7
Enable Call Waiting.
call_waiting.enable = 1
call_waiting.tone = 1
Set the W60B IP DECT PHONE
series to enable Call Waiting and Call
Waiting Tone.
Step 8
Enable MWI.
account.1.subscribe_mwi = 0
account.1.subscribe_mwi_expires
=3600
MWI: Solicited when setting
SubscribeMWI = 1.
MWI: Not solicited when setting
SubscribeMWI = 0.
Step 9
Enable negotiated DTMF type.
account.1.dtmf.type = 1
Set the W60B IP DECT PHONE to
enable inband or RFC 2833
negotiated DTMF.
Step 10
Select Transport Type.
account.1.sip_server.1.transport_
type = 0
Set the SIP transport:
Transport = 0 (UDP)
Transport = 1 (TCP)
Transport = 2 (TLS) (except T18P)
Transport = 3 (DNS-SRV) (except
T80P)
4.3 Subscriber Level Configuration
This section identifies the device-specific parameters, including registration and
authentication. These settings must be unique across devices to be matched with the
settings for a BroadWorks subscriber.
Provisioning a subscriber to register with BroadWorks allows calls to terminate to the
subscriber’s line. Registration requires that a unique address of record (AoR) is
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists
of setting the line/port parameter to a unique value within the Application Server cluster.
Step Command Purpose
Subscriber parameters for the <MACADDRESS>.cfg
Step 1
Enable line 1 to be used.
Example:
account.1.enable = 1
Enable a line of the W60B IP
DECT PHONE to be used.
Step 2
Configure display name for a
line.
Example:
account.1.display_name = Joe
For the line, configure the name to
be displayed on the device.

Table of Contents

Other manuals for Yealink W60B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink W60B and is the answer not in the manual?

Yealink W60B Specifications

General IconGeneral
Dimensions130mm x 100mm x 25.1mm
Operating Temperature0°C to +40°C
DECT StandardsCAT-iq 2.0
Number of HandsetsUp to 8
Internal CallsYes
External CallsYes
Call HoldYes
Call TransferYes
3-way ConferenceYes
Call WaitingYes
MuteYes
RedialYes
DECT Radio CoverageUp to 50m indoors, 300m outdoors
PoEIEEE 802.3af Class 1
ConfigurationBrowser/phone/auto-provision
Wall MountableYes
Wireless TechnologyDECT
Channels120
Concurrent CallsUp to 8 concurrent calls
Audio CodecsG.722, G.711, G.729, G.726, iLBC, Opus
SecurityTLS, SRTP, HTTPS, 802.1X
Operating Humidity10 ~ 95%
Handset Registration8 handsets
Frequency Bands1880-1900 MHz
Operating RangeUp to 50m indoors, 300m outdoors
Humidity10-95%
ComplianceCE, FCC, RCM
Network ProtocolsSIP, HTTP, HTTPS, DHCP, DNS, NTP, STUN
Number of SIP AccountsUp to 8 SIP accounts
Storage Temperature-30°C to +70°C