1. Introduction
1.1 Using the Magnetic Flowmeter Safely ........................2
1.2 Warranty ......................................................................4
1.3 Combination for Flowtube and Remote Converter .....4
2. Handling Precautions
2.1 CheckingModelandSpecications ............................5
2.2 Storage Precautions ...................................................5
3. Installation
3.1 Piping Design Precautions ..........................................6
3.2 Handling Precautions ..................................................8
3.3 Installation of Integral Flowmeter and Remote
Flowtube ......................................................................9
3.4 Installation of Remote Converter ............................. 27
4. Wiring
4.1 Wiring the Integral Flowmeter .................................. 29
4.2 Wiring the Remote Flowtube .................................... 35
4.3 Wiring the AXFA14 Remote Converter .................... 40
4.4 Wiring the AXFA11 Remote Converter .................... 46
5. Basic Operating Procedures
5.1 Operating Procedures Using the Display Unit ......... 52
5.2 OperatingPanelCongurationandFunctions......... 52
5.3 Display Unit Setting Methods ................................... 53
5.4 Parameter Setting Procedure .................................. 55
5.5 BRAIN / HART Connection ...................................... 57
6. Operation
6.1 Pre-operation Zero Adjustment ................................ 59
6.2 Zero Adjustment Using Display Unit Switches ......... 59
6.3 Write Protect Switch ................................................. 60
7. Errors and Countermeasures for Display unit
and BRAIN protocol
8. Parameter Summary
8.1 Menu tree for DD (HART 5) ...................................... 64
8.2 Parameter List (BRAIN) ........................................... 67
9. Approvals
10. Explosion Protected Type Instrument
10.1 ATEX ........................................................................ 77
10.2 FM ............................................................................ 77
10.3 CSA .......................................................................... 80
10.4 IECEx ....................................................................... 81
10.5 TIIS ........................................................................... 82
INSTALLATION AND OPERATING PRECAUTIONS
FOR TIIS FLAMEPROOF EQUIPMENT (EX-B03E)
1
2
3
4
5
6
7
9
8
10
AXF Series
Magnetic Flowmeter
Installation Manual
IM 01E20A01-01EN
IM 01E20A01-01EN
3rd Edition
Integral Flowmeter
(AXF

G,
AXF

C,
AXF

H)
Remote Converter
(AXFA14G, AXFA14C)
Remote Flowtube
(AXF

G,
AXF

C,
AXF

H,
AXF

W)
Remote Converter
(AXFA11G)
This manual outlines the basic guidelines for installation and wiring
procedures of the ADMAG AXF Series. For the items which are not
covered in this manual, see the user’s manuals in the following table.
Note: For F
OUNDATIONeldbusandPROFIBUSPAtype,referto
IM 01E20A01-02EN in addition to this manual.
For ATEX or IECEx explosion proof type, refer to
IM 01E20A01-11EN in addition to this manual.
Document No. Document Title
IM 01E20D01-01E
AXF Magnetic Flowmeter Integral Flowmeter/
Remote Flowtube [Hardware Edition]
IM 01E20C01-01E
AXFA11G Magnetic Flowmeter Remote Converter
[Hardware Edition/Software Edition]
IM 01E20C02-01E
AXFA14G/C Magnetic Flowmeter Remote Converter
[Hardware Edition/Software Edition]
AXF Magnetic Flowmeter Integral Flowmeter
[Software Edition]
Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA AXFA14G and is the answer not in the manual?

YOKOGAWA AXFA14G Specifications

General IconGeneral
BrandYOKOGAWA
ModelAXFA14G
CategoryMeasuring Instruments
LanguageEnglish

Summary

3. Installation

3.3 Installation of Integral Flowmeter and Remote Flowtube

Step-by-step instructions for installing integral flowmeters and remote flowtubes.

3.4 Installation of Remote Converter

Procedures for installing remote converters, including mounting options.

4. Wiring

4.1 Wiring the Integral Flowmeter

Detailed instructions for wiring the integral flowmeter.

4.2 Wiring the Remote Flowtube

Instructions for wiring the remote flowtube and its connections.

4.3 Wiring the AXFA14 Remote Converter

Wiring procedures specific to the AXFA14 remote converter.

4.4 Wiring the AXFA11 Remote Converter

Wiring procedures specific to the AXFA11 remote converter.

5. Basic Operating Procedures

6. Operation

6.1 Pre-operation Zero Adjustment

Procedure to ensure accurate zero flow readings before operation.

7. Errors and Countermeasures for Display unit and BRAIN protocol

8. Parameter Summary

10. Explosion Protected Type Instrument

10.1 ATEX

Requirements and specifications for ATEX explosion-proof type instruments.

10.2 FM

Technical data and standards for FM explosion-proof certification.

10.3 CSA

Technical data and standards for CSA explosion-proof certification.

Related product manuals