4-17
IM CW240E
Wiring
4
4.5 Carrying out Wiring
4.5.10 Three-phase Three-wire Three-current (3P3W3I)
<Three-power-meter method>
● WIRING DIAGRAM Screen ● WIRING CHECK Screen
● Actual Wiring
2S
1R
3T
2S
1R
3T
Power
supply
Load
Black
Red
Blue
NOTE
Do not connect a wire to terminal N of the voltage input terminals.
SEE ALSO
For more information on wiring checks, see Section 4.7, Checking Wiring.