5-106
IM 701310-17E
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:DFREquency
Function Sets the upper and lower limits between the peak
frequencies of the FFT search or queries the current
setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:DFREquency {<Freq
uency>,<Frequency>}
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:DFREquency?
<x> of SELect<x> = 1 to 4
<x> of FFT<x> = 1 or 2
<Frequency> = See the DL9000 User’s Manual
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:DFREQUENCY 1,10
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:DFREQUENCY?
-> :HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:
DFREQUENCY 10.00E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:DV
Function Sets the upper and lower limits between the peak
voltages of the FFT search or queries the current
setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:DV {<NRf>,<NRf>}
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:DV?
<x> of SELect<x> = 1 to 4
<x> of FFT<x> = 1 or 2
<NRf> = –4 to 4 (div)
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:DV 1,2
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:DV? -> :HISTORY:
CURRENT:SEARCH:SELECT1:PARAMETER:FFT1:
PEAK:DV 2.000E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:FREquency<x>
Function Sets the upper and lower limits of the peak frequency
of the FFT search or queries the current setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:FREquency<x>
{<Frequency>,<Frequency>}
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:FREquency<x>?
<x> of SELect<x> = 1 to 4
<x> of FFT<x> = 1 or 2
<x> of FREQuency<x> = 1 or 2
<Frequency> = See the DL9000 User’s Manual
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:FREQUENCY1 1,2
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:FREQUENCY1?
-> :HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:
FREQUENCY1 2.000E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:V<x>
Function Sets the upper and lower limits of the peak voltage of
the FFT search or queries the current setting.
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:V<x>
{<NRf>,<NRf>}
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:FFT<x>:PEAK:V<x>?
<x> of SELect<x> = 1 to 4
<x> of FFT<x> = 1 or 2
<x> of V<x> = 1 or 2
<NRf> = –4 to 4 (div)
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:V1 1,2
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:FFT1:PEAK:V1? -> :HISTORY:
CURRENT:SEARCH:SELECT1:PARAMETER:FFT1:
PEAK:V1 2.000E+00,1.000E+00
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:MEASure?
Function Queries all settings related to the search using
automated measurement of waveform parameters
(measure search).
Syntax
:HISTory[:CURRent][:SEARch]:SELect<x>:
PARameter:MEASure?
<x> = 1 to 4
Example
:HISTORY:CURRENT:SEARCH:SELECT1:
PARAMETER:MEASURE? -> :HISTORY:CURRENT:
SEARCH:SELECT1:PARAMETER:MEASURE:
CALCULATION1 1.000E+00,2.000E+00
5.14 HISTory Group

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL9040 and is the answer not in the manual?

YOKOGAWA DL9040 Specifications

General IconGeneral
BrandYOKOGAWA
ModelDL9040
CategoryTest Equipment
LanguageEnglish

Related product manuals