EasyManua.ls Logo

YOKOGAWA DL9040 - Page 220

YOKOGAWA DL9040
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-186
IM 701310-17E
:TRIGger:ENHanced:I2CBus:CLOCk:SOURce
Function Sets the clock trace of the I
2
C bus trigger or queries
the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:CLOCk:
SOURce {<NRf>}
:TRIGger:ENHanced:I2CBus:CLOCk:SOURce?
<NRf> = 1 to 4
Example
:TRIGGER:ENHANCED:I2CBUS:CLOCK:SOURCE 1
:TRIGGER:ENHANCED:I2CBUS:CLOCK:SOURCE?
-> :TRIGGER:ENHANCED:I2CBUS:CLOCK:
SOURCE 1
:TRIGger:ENHanced:I2CBus:DATA?
Function Queries all settings related to the data of the I
2
C bus
trigger.
Syntax
:TRIGger:ENHanced:I2CBus:DATA?
<x> = 1 or 2
Example
:TRIGGER:ENHANCED:I2CBUS:DATA?
->
:TRIGGER:ENHANCED:I2CBUS:DATA:BYTE 1;
CONDITION TRUE;DPOSITION 1;MODE 1;
PATTERN1 "10101011";
PATTERN2 "10101010";
PATTERN3 "10101111";
PATTERN4 "10101011";PMODE DONTCARE;
SOURCE 1
:TRIGger:ENHanced:I2CBus:DATA:BYTE
Function Sets the number of data bytes of the I
2
C bus trigger
or queries the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
BYTE {<NRf>}
:TRIGger:ENHanced:I2CBus:DATA:BYTE?
<NRf> = 1 to 4
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:BYTE 1
:TRIGGER:ENHANCED:I2CBUS:DATA:BYTE?
-> :TRIGGER:ENHANCED:I2CBUS:DATA:BYTE 1
:TRIGger:ENHanced:I2CBus:DATA:
CONDition
Function Sets the determination method (match or not match)
of the data of the I
2
C bus trigger or queries the
current setting.
Syntax
:TRIGger:ENHanced:I2CBus:DATA:
CONDition {FALSe|TRUE}
:TRIGger:ENHanced:I2CBus:DATA:
CONDition?
Example
:TRIGGER:ENHANCED:I2CBUS:DATA:
CONDITION TRUE
:TRIGGER:ENHANCED:I2CBUS:DATA:
CONDITION? -> :TRIGGER:ENHANCED:I2CBUS:
DATA:CONDITION TRUE
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:HEXA
Function Sets the Sub address of the 7-bit + Sub address of
the I
2
C bus trigger in hexadecimal notation.
Syntax
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:HEXA {<String>}
<String> = 2 characters by combining ‘0’ to ‘F’
and ‘X’
Example
:TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:HEXA "EF"
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:PATTern
Function Sets the Sub address of the 7-bit + Sub address of
the I
2
C bus trigger in binary notation or queries the
current setting.
Syntax
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:PATTern {<String>}
:TRIGger:ENHanced:I2CBus:ADATa:
BIT7APsub:SADDress:PATTern?
<String> = 8 characters by combining ‘0,’ ‘1,’
and ‘X’
Example
:TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:PATTERN "10101011"
:TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:PATTERN? -> :
TRIGGER:ENHANCED:I2CBUS:ADATA:
BIT7APSUB:SADDRESS:PATTERN "10101011"
:TRIGger:ENHanced:I2CBus:ADATa:TYPE
Function Sets the address type of the I
2
C bus trigger or queries
the current setting.
Syntax
:TRIGger:ENHanced:I2CBus:ADATa:
TYPE {BIT10address|BIT7ADdress|
BIT7APsub}
:TRIGger:ENHanced:I2CBus:ADATa:TYPE?
Example
:TRIGGER:ENHANCED:I2CBUS:ADATA:
TYPE BIT10ADDRESS
:TRIGGER:ENHANCED:I2CBUS:ADATA:TYPE?
-> :TRIGGER:ENHANCED:I2CBUS:ADATA:
TYPE BIT10ADDRESS
:TRIGger:ENHanced:I2CBus:CLOCk?
Function Queries all settings related to the clock of the I
2
C bus
trigger.
Syntax
:TRIGger:ENHanced:I2CBus:CLOCk?
Example
:TRIGGER:ENHANCED:I2CBUS:CLOCK?
-> :TRIGGER:ENHANCED:I2CBUS:CLOCK:
SOURCE 1
5.29 TRIGger Group

Table of Contents

Related product manuals