SET OPTIONS
Parameter Allowable range Description
STEERING TYPE
(T, TM)
NONE ÷ ANALOG It allows to select which type of steering unit is connected to
the controller.
NONE = NO steering module is present on the truck,
ACE0/COMBIAC0 does not wait for CAN message by
the EPS and it does not apply EPS and braking steer
cutback.
OPTION#1 = EPS is present and it is configured with
an ENCODER + TOGGLE SWITCHES. These signals
are transmitted to ACE0/COMBIAC0 over CAN bus.
OPTION#2 = EPS is present and it is configured with a
POT + ENCODER. These signals are transmitted to
ACE0/COMBIAC0 over CAN bus.
ANALOG = A hydraulic steer is used on the truck and
ACE0/COMBIAC0 is reading through one of its analog
input the signal coming from a wheel potentiometer in
order to read the wheel rotation.
M.C. FUNCTION
(A)
OFF ÷ OPTION#2 This parameter defines the configuration of the NLC output
(A12), dedicated to the main – or line – contactor.
OFF = Main contactor is not present. Diagnoses are
masked and MC is not driven.
ON = Main contactor is in standalone configuration.
Diagnoses are performed and MC is closed after
key-on only if they have passed.
OPTION#1 = For a traction-and-pump setup, with only
one main contactor for both controllers. Diagnoses are
performed and MC is closed after key-on only if they
have passed.
OPTION#2 = For a traction-and-pump setup, with two
main contactors. Each controller drives its own MC.
Diagnoses are performed and MCs are closed after
key-on only if they have passed.
M.C. OUTPUT
(T, TM, P, CO)
ABSENT, PRESENT This parameter defines whether a load coil is connected to
the NLC output (A12) or not.
ABSENT = NLC output is not connected to any load
coil.
PRESENT = NLC output is connected to a load coil (by
default, that of the main contactor).
EBRAKE ON APPL.
(T, TM, P, CO)
ABSENT, PRESENT This parameter defines whether the application includes an
electromechanical brake or not.