AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual Page – 83/155
TESTER (Master µC)
Parameter
Unit of measure
(resolution)
Description
A9 OUTPUT EV1
(A)
OFF/ON Status of the EV1 output (pin A9).
A11 OUTPUT EV2
(A)
OFF/ON Status of the EV2 output (pin A11).
A33 OUTPUT EV3
(A)
OFF/ON Status of the EV3 output (pin A33).
A34 OUTPUT EV4
(A)
OFF/ON Status of the EV4 output A34.
A8 OUTPUT EV5
(A)
OFF/ON Status of the EV5 output A8.
A26 OUTPUT HORN
(A)
OFF/ON It shows the status of the HORN output (pin A26)..
A12 MAIN CONT.
(A)
% (1%) Voltage applied over the main contactor coil. It
corresponds to the duty cycle value of PWM applied,
expressed as percentage.
A4 ELEC.BRAKE
(A)
% (1%) Voltage applied over the electromechanical brake coil. It
corresponds to the duty cycle value of PWM applied,
expressed as percentage.
CTRAP HW
(A)
Units (1) Counter showing the number of occurrences of hardware-
overcurrent detection.
CTRAP THRESOLD
(A)
Volt (0.01 V) Threshold voltage of the overcurrent detection circuit.
A.SENS.OFFSET SR
(Only for BLE0 with
sin/cos sens)
(A)
Digital units (1) Voltage offset of the sine signal, acquired during the
automatic acquisition of the sin/cos sensor.
A.SENS.OFFSET CR
(Only for BLE0 with
sin/cos sens)
(A)
Digital units (1) Voltage offset of the cosine signal, acquired during the
automatic acquisition of the sin/cos sensor.
ANGLE OFFSET
(Only for BLE0 with
sin/cos sens)
(A)
Degrees (0.1°) Angular offset between the stator and the sin/cos sensor.