Symbologies 13 - 39
Clear Transmission Buffer
To clear the transmission buffer, scan the Clear Buffer bar code below, which contains only a start character, a
dash (minus), and a stop character.
•
The digital scanner issues a short high/low/high beep.
•
The digital scanner erases the transmission buffer.
•
No transmission occurs.
Transmit Buffer
There are two methods to transmit the Code 39 buffer.
1. Scan the Transmit Buffer bar code below, which contains only a start character, a plus (+), and a stop
character.
• The digital scanner transmits and clears the buffer.
• The digital scanner issues a low/high beep.
2. Scan a Code 39 bar code with a leading character other than a space.
• The digital scanner appends new decode data to buffered data.
• The digital scanner transmits and clears the buffer.
• The digital scanner signals that it transmitted buffer with a low/high beep.
• The digital scanner transmits and clears the buffer.
Clear Buffer
NOTE The Clear Buffer contains only the dash (minus) character. To scan this command, set Code 39 lengths to
include length 1.
Transmit Buffer
NOTE The Transmit Buffer contains only a plus (+) character. To scan this command, set Code 39 lengths to
include length 1.