Decoding Preferences 5 - 5
Low Light Enhancement
Parameter # F1h, 64h
In presentation mode, selecting Enable Low Light Enhancement causes illumination to remain on at a low level
in low lighting conditions. Select Disable Low Light Enhancement to prevent illumination from remaining on
under these conditions.
Presentation Mode Field of View
Parameter # F1h, 61h
In presentation mode, the scanner searches for a bar code in a smaller region around the aiming pattern’s center
cross to speed search time.
To use a full field of view, scan Presentation Mode Full Field of View. This allows the scanner to search the larger
area of the aiming pattern.
Enable Low Light Enhancement
(01h)
*Disable Low Light Enhancement
(00h)
*Presentation Mode Default Field of View
(01h)
Presentation Mode Full Field of View
(02h)

Table of Contents

Other manuals for Zebra DS4308

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS4308 and is the answer not in the manual?

Zebra DS4308 Specifications

General IconGeneral
SealingIP42
ConnectivityUSB, RS232, Keyboard Wedge, TGCS (IBM) 46XX over RS485
Decode Capability1D, 2D, PDF417
Drop SpecificationWithstands multiple 1.5 m (5 ft) drops to concrete
Operating Temperature32° to 104° F/0° to 40° C
Storage Temperature-40° to 158° F/-40° to 70° C
Humidity5% to 95% (non-condensing)
Weight5.7 oz./161.9 g
Dimensions6.5 in. H x 2.6 in. W x 3.6 in. D 16.5 cm H x 6.6 cm W x 9.1 cm D