4 - 2 DS3408 Product Reference Guide
Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan
the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-6. The digital scanner issues a
fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning several
bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences Parameter Defaults
Table 4-1 lists defaults for user preferences parameters. To change the default values, scan the appropriate bar
codes in this guide. These new values replace the standard default values in memory. To recall the default
parameter values, scan *Set Defaults on page 4-4.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
Table 4-1
User Preferences Default Table
Parameter
Parameter
Number
Default
Page
Number
User Preferences
Set Default Parameter Set Defaults
4-4
Parameter Scanning ECh Enable
4-5
Beeper Tone 91h Medium
4-6
Beeper Volume 8Ch High
4-7
Suppress Power-up Beeps F1h D1h Do not suppress
4-7
Power Mode 80h Continuous On
4-8
Time Delay to Low Power Mode 92h 1 Minute
4-9
Trigger Mode 8Ah Auto Aim
4-11
Picklist Mode F0h 92h Disabled Always
4-12
Decode Session Timeout 88h 9.9 Sec
4-13
Timeout Between Decodes, Same Symbol 89h 0.6 Sec
4-13