MultiBio700- User Manual
eSSL Pvt. Ltd. Page 80
will be refused by “anti-pass back” function. For example, a user’s recent record is “in”,
his second record can be “out” or “in”. His third record is based on his second record.
Out record and in record must match.Notice: If customer has no record before, then
he can come in but cannot go out. )
When the master machine is set as “in anti-pass back”, if the user wants to come in and
go out normally, his recent record must be “out”, or he cannot go out. Any out record will
be “anti-pass back refused” by the system. (Notice: If the customer has no former
record, then he can go out, but cannot come in).
When the master machine is set as “out-in anti-pass back”, if the user wants to come in
and go out normally, if his recent record is “out” and “in”, then his next record must be
“in” and “out”.
operation
1. Select model
Master machine: The machine with Wiegand in function, except for F10 reader.
Slave machine: The machine with Wiegand Out function.
2. Menu setting
Anti-pass back
There are four options: in/out anti-pass back, out anti-pass back, in anti-pass back, and
none.
Out anti-pass back: Only user’s last record is in-record, can the door be open.
In anti-pass back: Only user’s last record is out-record, can the door be open.
Device status: There are three options: Control-in, control-out and none
Control-in: When it is set, the verified records on the device are in-records.
Control-out: When it is set, the verified records on the device are out-records.
None: When it is set, close the device’s anti-pass back function.
3. Modify device’s Wiegand output format
When the two devices are communicating, only the Wiegand signals without device ID
are received. Enter device menu> communication option> Wiegand option or enter
software -> basic setting -> device management -> Wiegand, to modify “defined format”
as “wiegand26 without device ID”.