ZXR108900SeriesHardwareInstallationManual
TABLE7INSTALLINGTHEBASEDIRECTLYMARKINGSIZE
CabinetName
AB
C
D
19D6H20
Cabinet
600496L2+52L1+40
19D8H20
Cabinet
19D8H20EMC
Cabinet
19D8H20EMC
Standardcabinet
800696L2+52L1+40
19D10H20
Cabinet
19D10H20
Alternateserver
Cabinet
19D10H20Direct
serverCabinet
100696L2+152L1+40
L1isthedistancefromsidegateandtothewallofcabinet
room,L1ā„900mm.
L2isthedistancefromfrontgatetothewallofcabinetroom,
L2ā„1500mm.
Note:
Verifymeasurementaftermarkingofallinstallationholesto
avoidmistakeandmakesurethatallmeasurementsarecor-
rect.
2.Drilling
DrillĻ14attheexpansionboltholemarkedontheīoorwith
adepthof90mm.
Makesuredrillisperpendiculartoīoorwhendrillingwithper-
cussiondrill(orhammer).Holdhandletightlyandverticallyto
avoidsway,otherwisetheīoorwillbedamagedandholewill
beenlargedandinclined.
Whenīooristoosliptopositiondrillbit,cutadentatthe
perforationpositionwithpunchīærsttohelplocatingdrillbit.
Useavacuumcleanertoremovethedustafterdrilling.
3.Expansionboltinstallation
Beforeinstallation,cleanupdustinsideandoutsideholeswith
avacuumcleaner .
Removewasherandnutfromexpansionbolt(M12Ć80),and
putexpansionboltandexpansiontubeintohole.Hammerex-
pansionboltusingarubberhammeruntilfullexpansiontube
oftheexpansionboltentersintoīoor .
Theinstallationofsinglecabinetexpansionboltisshownin
Figure23.
30ConīædentialandProprietaryInformationofZTECORPORATION