Chapter 33 Cluster Management
MES-3728 User’s Guide
285
Figure 166 Management > Cluster Management > Configuration
The following table describes the labels in this screen.
Table 113 Management > Cluster Management > Configuration
LABEL DESCRIPTION
Clustering Manager
Active Select Active to have this Switch become the cluster manager switch. A cluster
can only have one manager. Other (directly connected) switches that are set to
be cluster managers will not be visible in the Clustering Candidates list. If a
switch that was previously a cluster member is later set to become a cluster
manager, then its Status is displayed as Error in the Cluster Management
Status screen and a warning icon ( ) appears in the member summary list
below.
Name Type a name to identify the Clustering Manager. You may use up to 32
printable characters (spaces are allowed).
VID This is the VLAN ID and is only applicable if the Switch is set to 802.1Q VLAN.
All switches must be directly connected and in the same VLAN group to belong
to the same cluster. Switches that are not in the same VLAN group are not
visible in the Clustering Candidates list. This field is ignored if the Clustering
Manager is using Port-based VLAN.