Chapter 7 Basic Setting
MES-3728 User’s Guide
76
The following table describes the labels in this screen.
7.3 General Setup
Use this screen to configure general settings such as the system name and time. Click Basic
Setting > General Setup in the navigation panel to display the screen as shown.
Table 8 Basic Setting > System Info
LABEL DESCRIPTION
System Name This field displays the descriptive name of the Switch for identification purposes.
ZyNOS F/W
Version
This field displays the version number of the Switch 's current firmware including the
date created.
Ethernet
Address
This field refers to the Ethernet MAC (Media Access Control) address of the Switch.
Hardware Monitor
Temperature
Unit
The Switch has temperature sensors that are capable of detecting and reporting if the
temperature rises above the threshold. You may choose the temperature unit
(Centigrade or Fahrenheit) in this field.
Temperature BOARD, MAC and PHY refer to the location of the temperature sensors on the
Switch printed circuit board.
Current This shows the current temperature at this sensor.
MAX This field displays the maximum temperature measured at this sensor.
MIN This field displays the minimum temperature measured at this sensor.
Threshold This field displays the upper temperature limit at this sensor.
Status This field displays Normal for temperatures below the threshold and Error for those
above.
Fan Speed
(RPM)
A properly functioning fan is an essential component (along with a sufficiently
ventilated, cool operating environment) in order for the device to stay within the
temperature threshold. Each fan has a sensor that is capable of detecting and
reporting if the fan speed falls below the threshold shown.
Current This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX This field displays this fan's maximum speed measured in Revolutions Per Minute
(RPM).
MIN This field displays this fan's minimum speed measured in Revolutions Per Minute
(RPM). "<41" is displayed for speeds too small to measure.
Threshold This field displays the minimum speed at which a normal fan should work.
Status Normal indicates that this fan is functioning above the minimum speed. Error
indicates that this fan is functioning below the minimum speed.
Voltage(V) The power supply for each voltage has a sensor that is capable of detecting and
reporting if the voltage falls out of the tolerance range.
Current This is the current voltage reading.
MAX This field displays the maximum voltage measured at this point.
MIN This field displays the minimum voltage measured at this point.
Threshold This field displays the percentage tolerance of the voltage with which the Switch still
works.
Status Normal indicates that the voltage is within an acceptable operating range at this
point; otherwise Error is displayed.