Chapter 3 Hardware Overview
MES-3728 User’s Guide
47
Figure 14 Removing the Fiber Optic Cables
Figure 15 Opening the Transceiver’s Latch Example
Figure 16 Transceiver Removal Example
3.1.4 Management Port
The MGMT (management) port is used for local management. Connect directly to this port
using an Ethernet cable. You can configure the Switch via Telnet or the web configurator.
The default IP address of the management port is 192.168.0.1 with a subnet mask of
255.255.255.0.
3.1.5 Power Connector
" Make sure you are using the correct power source as shown on the panel.
To connect power to the Switch, insert the female end of the power cord to either the AC or
DC power receptacle on the front panel, depending on your power source. Connect the other
end of the supplied power cord to a power outlet. Make sure that no objects obstruct the
airflow of the fans (located on the side of the unit).
The AC model requires a power supply of 100-240 VAC, 50/60 Hz, 0.55 A Max. The DC
model requires a power supply of -36 VDC ~ -72 VDC, 0.66 A Max. The AC/DC version can
be used with either power specifications.
See Chapter 38 on page 299 for information on the Switch’s power supply requirements.