Chapter 11 Routing
ZyWALL USG Series User’s Guide
416
Figure 287 Configuration > Network > Routing > Static Route > Add (IPv4 Configuration)
Figure 288 Configuration > Network > Routing > Static Route > Add (IPv6 Configuration)
The following table describes the labels in this screen.
Table 140 Configuration > Network > Routing > Static Route > Add
LABEL DESCRIPTION
Destination IP This parameter specifies the IP network address of the final destination. Routing is always
based on network number.
If you need to specify a route to a single host, enter the specific IP address here and use a
subnet mask of 255.255.255.255 (for IPv4) in the Subnet Mask field or a prefix of 128 (for IPv6) in
the Prefix Length field to force the network number to be identical to the host ID.
For IPv6, if you want to send all traffic to the gateway or interface specified in the Gateway IP
or Interface field, enter :: in this field and 0 in the Prefix Length field.
Subnet Mask Enter the IP subnet mask here.
Prefix Length Enter the number of left-most digits in the destination IP address, which indicates the network
prefix. Enter :: in the Destination IP field and 0 in this field if you want to send all traffic to the
gateway or interface specified in the Gateway IP or Interface field.
Gateway IP Select the radio button and enter the IP address of the next-hop gateway. The gateway is a
router or switch on the same segment as your Zyxel Device's interface(s). The gateway helps
forward packets to their destinations.
Interface Select the radio button and a predefined interface through which the traffic is sent.
Metric Metric represents the “cost” of transmission for routing purposes. IP routing uses hop count as
the measurement of cost, with a minimum of 1 for directly connected networks. Enter a
number that approximates the cost for this link. The number need not be precise, but it must
be 0~127. In practice, 2 or 3 is usually a good number.
OK Click OK to save your changes back to the Zyxel Device.
Cancel Click Cancel to exit this screen without saving.