EasyManua.ls Logo

ZyXEL Communications USG40W - Firmware Upgrade Via USB Stick; The Shell Script Screen

ZyXEL Communications USG40W
1090 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 46 File Manager
ZyWALL USG Series User’s Guide
993
If the upload was not successful, the following message appears in the status bar at the bottom of the
screen.
Figure 706 Firmware Upload Error
46.3.4 Firmware Upgrade via USB Stick
In addition to uploading firmware via the web configurator or console port (see the CLI Reference
Guide), you can also upload firmware directly from a USB stick connected to the Zyxel Device.
1 Create a folder on the USB stick called ‘/[ProductName_dir]/firmware’. For example, if your Zyxel Device
is USG110, then create a ‘/usg110_dir/firmware/’ folder on the stick.
2 Put one firmware ‘bin’ file into the firmware folder. Make sure the firmware ID and version number are
correct for your model (the firmware ID is in brackets after the firmware version number - for USG100 it is
AAPH).
Note: Do not put more than one firmware ‘bin’ file into the firmware folder.
The firmware version in the USB stick must be different to the currently running firmware.
If the firmware on the USB stick is older, then the Zyxel Device will ‘upgrade’ to the older
version. It is recommended that the firmware on the USB stick be the latest firmware
version.
3 Insert the USB stick into the Zyxel Device. The firmware uploads to the standby system space.
4 The SYS LED blinks when the Zyxel Device automatically reboots making the upgraded firmware in
standby become the running firmware.
Note: If the startup-config.conf configuration file has problems and you are upgrading to 4.25
or later firmware, then the Zyxel Device will revert (failover) to the previously running
firmware.
If the startup-config.conf configuration file has problems and you are upgrading to
earlier than 4.25 firmware, then the Zyxel Device uses the new earlier firmware, but
generates a log and tries the existing lastgood.conf configuration file. If there isn’t a
lastgood.conf configuration file or it also has an error, the Zyxel Device applies the
system-default.conf configuration file.
46.4 The Shell Script Screen
Use shell script files to have the Zyxel Device execute commands that you specify. Use a text editor to
create the shell script files. They must use a “.zysh” filename extension.

Table of Contents

Other manuals for ZyXEL Communications USG40W

Related product manuals