202 / 241
G +U
IN
WIEGAND OUTactive supply LED indicator
TAMPER Tamper switch (Part No. 9155038) input
Wiegand Input Technical Parameters
Current 5 mA
Input resistance 680 Ohm
Pulse length 50 μs
Delay between pulses approx. 2 ms
Recommended Wiring Diagram for Reader with Bus Driver
Recommended Wiring Diagram for Reader with Open Collector (OC) Output