266 | Managing the Radio
Aprisa SR+ User Manual 1.11.1
FEC DISABLE
FEC Disable
This diagnostic function allows the user to temporarily disable forward error correction on the channel when
diagnosing problems on the link.
Therefore, enabling this diagnostic function would temporarily disable FEC on the channel and the
associated maintenance mode alarm would activate.
Note that the opposite is not true for this diagnostic function. In other words, this diagnostic function does
not provide the user with the option to temporarily enable forward error correction on the channel.
All diagnostic functions are not persistent and will be return to disabled states should the system restart.
Option
Function
Enable
Enables the FEC Disable diagnostic function
Disable
Disables the FEC Disable diagnostic function
Timer
Allows the FEC to be disabled but only for a predetermined period.
Duration (s)
This parameter defines the period required for disabling of the FEC. When this period elapses, the FEC is
enabled.