Managing the Radio | 341
Aprisa SR+ User Manual 1.11.1
Terminal
Protected Station: Terminal > Summary
TERMINAL SUMMARY
This page displays the current settings for the Terminal parameters.
PROTECTION INFORMATION
Protection Type
This parameter shows the type of protection:
Option
Function
Serial Data Driven Switching
Provides radio and RS-232 serial port user interface protection for
Aprisa SR+ radios.
Monitored Hot Standby
(Protected Station)
The RF ports and interface ports from two standard Aprisa SR+
radios are switched to the standby radio if there is a failure in the
active radio.
The standby radio is monitored to ensure its correct operation
should a switch-over be required. See ā€˜Monitored Alarms’ on page
409 for the list of monitored alarms.
Redundant
(Protected Station)
The RF ports and interface ports from two standard Aprisa SR+
radios are switched to the standby radio if there is a failure in the
active radio
Active Unit
This parameter shows the radio which is currently active (Primary or Secondary).