Installation Manual Digital sets - IP Sets - SIP Sets AMT/PTD/TR/0001/3/7/EN
Appendix 05/2008 Page 16-5
The definition screen for the New class is displayed:
Enter the following in sequence:
- Class name (free syntax),
- Description (optional free syntax),
- Identifier of the DHCP server client vendor.
Identifier of the DHCP server client vendor.
This option identifies a DHCP client type (Vendor class). This identifier is defined by a string of n
bytes. A distributor can define a class identifier to exchange proprietary information between the
clients and server.
Special features of i740N (or i740 as of set software release 5.2A): to enable the DHCP server send
the two PBX addresses (network configuration parameters) to i740N (or i740) sets, a second provider
class must be created on the server, with the identifier "CONNEXITY-001".
The values used for i7xx range IP sets are:
- “ -000 ” stands for the version of this specification for IP sets awaiting only one PBX IP
address,
- “ -001 ” stands for the version of this specification for IP sets awaiting two PBX IP
addresses, such as i740N.
Click OK to validate the procedure,
Opt Log
60 13 C O N N E X I T Y - 0 0 0
60 13 C O N N E X I T Y - 0 0 1