140 ACQ550-U1 User’s Manual
Parameters
3612 START DAY 3
Defines timer 3 weekly start day.
See parameter 3604.
3613 STOP DAY 3
Defines timer 3 weekly stop day.
See parameter 3605.
3614 START TIME 4
Defines timer 4 daily start time.
See parameter 3602.
3615 STOP TIME 4
Defines timer 4 daily stop time.
See parameter 3603.
3616 START DAY 4
Defines timer 4 weekly start day.
See parameter 3604.
3617 STOP DAY 4
Defines timer 4 weekly stop day.
See parameter 3605.
3622 BOOSTER SEL
Selects the source for the booster signal.
0 =
NOT SEL – Booster signal is disabled.
1 =
DI1 – Defines DI1 as the booster signal.
2…6 =
DI2…DI6 – Defines DI2…DI6 as the booster signal.
-1 =
DI1(INV) – Defines an inverted digital input DI1 as the booster signal.
-2…-6 =
DI2(INV)…DI6(INV) – Defines an inverted digital input DI2…DI6 as the booster signal.
3623 BOOSTER TIME
Defines the booster ON time. Time is started when booster sel
signal is released. If parameter value is 01:30:00, booster is
active for 1 hour and 30 minutes after activation DI is released.
3626 TIMED FUNC 1 SRC
Defines the time periods used by the timer.
0 =
NOT SEL – No time periods have been selected.
1 =
T1 – Time Period 1 selected in the timer.
2 =
T2 – Time Period 2 selected in the timer.
3 =
T1+T2 – Time Periods 1 and 2 selected in the timer.
4 =
T3 – Time Period 3 selected in the timer.
5 =
T1+T3 – Time Periods 1 and 3 selected in the timer.
6 =
T2+T3 – Time Periods 2 and 3 selected in the timer.
7 =
T1+T2+T3 – Time Periods 1, 2 and 3 selected in the timer.
8 =
T4 – Time Period 4 selected in the timer.
9 =
T1+T4 – Time Periods 1 and 4 selected in the timer.
10 =
T2+T4 – Time Periods 2 and 4 selected in the timer.
11 = T1+T2+T4 – Time Periods 1, 2 and 4 selected in the timer.
12 =
T3+T4 – Time Periods 3 and 4 selected in the timer.
13 =
T1+T3+T4 – Time Periods 1, 3 and 4 selected in the timer.
14 =
T2+T3+T4 – Time Periods 2, 3 and 4 selected in the timer.
15 =
T1+T2+T3+T4 – Time Periods 1, 2, 3 and 4 selected in the timer.
16 =
BOOSTER – Booster selected in the timer.
17 =
T1+B – Booster and Time Period 1 selected in the timer.
18 =
T2+B – Booster and Time Period 2 selected in the timer.
19 =
T1+T2+B – Booster and Time Periods 1 and 2 selected in the timer.
20 =
T3+B – Booster and Time Period 3 selected in the timer.
Code Description
Booster active
Activation DI
Booster time

Table of Contents