EasyManua.ls Logo

ABB ETL600 - Section 3

ABB ETL600
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ABB Switzerland Ltd 1KHW001491-EN
Tuning Instructions for Rx RF Filter P4RX <ETL600 Rel.1>
Archive No.:
-
Rev.
A
Date:
05-11-16
Responsible Department: Prepared: Approved: Distribution: Lang.: Page:
PTUKT 2005-07-05 H. Hoitink 2005-11-16 H. Benninger - EN 1/7
Valid for: Derived from: Replaces: Classification-No.: File:
1KHL015117-EN - 1KHW001491ae Tuning Instructions
for Rx RF Filter P4RX.doc
Powerline Carrier Equipment: Series ETL600
Tuning Instructions for Rx RF Filter P4RX <ETL600 Rel.1>
Contents
1
General ........................................................................................................... 2
2 Programming .................................................................................................. 2
2.1 Steps for determining the required jumper positions............................ 2
3 Tuning the filter circuits individually ................................................................ 3
3.1 Steps for tuning the coils L1 and L2..................................................... 3
4 Checking the gain and frequency response of the filter ................................. 4
4.1 Steps to check the gain setting ............................................................ 4
4.2 Steps to check the frequency response ............................................... 5
5 Test circuits..................................................................................................... 6
Test conditions:
Temperature range: 10 °C to 40 °C.
List of test equipment:
PC with Windows 2000 or XP
HMI600 software
PC Ù P4LT cable 1:1 serial RS-232
Tx tuning adapter P3LL HENF209668
Rx tuning adapter P4LM HENF209665
RF test cable 50 Ohm V9MW, BNC to
SSMB (mini coax), 2 cables required
1KHL015238R0001
Level meter, wide band or selective,
10 kHz to 1 MHz.
Preferably 50 Ohm input, 75 Ohm may also
be used
SPM-33A (Acterna) or equivalent;
featuring both wide band as well as
selective measurements
Plastic tuning screwdriver
Notes:
Level measurements during tuning & checking frequency response of P4RX are relative. Hence any ordinary
wide band or selective level meter with a frequency range 10 kHz to 1000 kHz can be used. Normally a wide
band level meter will be sensitive enough. If more sensitivity is required, use a selective one. Be careful when
using a wide band meter, as unwanted signals may disturb the measurement.
The same Rx tuning adapter P4LM used for ETL 41 and ETL500 can be used for ETL600. However, if two
shorting wires are present on the P4LM, they must be removed. The position of these 2 shorting wires - if
present - will be across C1-C9 & C2-C10, under the sub-board.