EasyManuals Logo

ABB ETL600 User Manual

ABB ETL600
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #273 background imageLoading...
Page #273 background image
Revision: Language: Page:
A EN 5/7
1KHW001491-EN
6. Connect the BNC connector OUT of P3LL with the RX RF-IN (50 Ohm input) SSMB connector on the
P4RX board.
7. Connect the level meter 50 Ohm (or 75 Ohm) to the RX RF-OUT (50 Ohm output) SSMB connector of
the P4RX board. Read the indicated level in dB.
If a 50 Ohm instrument is used, designate this measured level as B.
If a 75 Ohm instrument is used, subtract 1.58 dB from the measured level. Designate this result as
B.
8. (B-A) is the gain of the P4RX board. Now the following condition should be fulfilled:
for F0 500 kHz: (B-A) = 0 dB ±1.5 dB
for F0 > 500 kHz: (B-A) = 0 dB +1.5 dB / -3.0 dB
4.2 Steps to check the frequency response
Refer also to chapter 5 “Test circuits”, Figure 2.
1. The Tx tuning adapter P3LL is inserted in place of the RF hybrid (P3LE).
)
Note: The RF hybrid must not be plugged on top of P3LL.
2. The P3LL tuning adapter is set for the following for the entire process:
FUNCTION A
Position of S1 L2
Position of S2 FILTER
Position of S3 Don't care
Position of LOAD Don't care
3. The P4RX module is plugged directly into the rack.
4. Connect the BNC connector OUT of P3LL with the RX RF-IN connector on P4RX.
Connect the level meter (50 or 75 Ohm) to the RX RF-OUT connector of P4RX.
Because the P3LL output is a high impedance source, the signal level at 50/75 Ohm will be quite
small. But mostly a wide band level meter still will be sensitive enough. If not, use a more sensitive
selective level meter to get reliable measurements.
5. In the Tuning Rx RF filter dialog box, click Check Rx RF filter to get the dialog box Check filter.
6. Click Activate f0 – 0.5
·B
Rx
(B
Rx
= 4, 8, 16 or 32 kHz). Measure the voltage at RX RF-OUT in dB and
check the pass condition given in dialog box.
7. Click Activate f0 + 0.5
·B
Rx
(B
Rx
= 4, 8, 16 or 32 kHz). Measure the voltage at RX RF-OUT in dB and
check the pass condition given in dialog box.
8. If the conditions checked in steps 6 and 7 are fulfilled, the pass band ripple of the filter is within
specifications
9. With the next tests, the filter selectivity is checked.
Click Activate f0 – 2
·B
Rx
(B
Rx
= 4, 8, 16 or 32 kHz). Measure the voltage at RX RF-OUT in dB and
check the pass condition given in dialog box.
10. Click Activate f0 + 2
·B
Rx
. (B
Rx
= 4, 8, 16 or 32 kHz). Measure the voltage at RX RF-OUT in dB and
check the pass condition given in dialog box.
11. If the conditions checked in steps 9 and 10 are fulfilled, the selectivity of the filter is within
specifications
12. Click Deactivate frequency and Close.
13. Click Cancel.
14. Remove tuning adapter P3LL and insert the RF hybrid (P3LE) back into the rack.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ETL600 and is the answer not in the manual?

ABB ETL600 Specifications

General IconGeneral
BrandABB
ModelETL600
CategoryTouch terminals
LanguageEnglish

Related product manuals