FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D 135
Flowmeter sensor in high temperature version
***
Lining material Flange material Ambient temperature range (T
amb.
)
Measuring medium temperature (T
medium
)
Minimum Maximum
Minimum Maximum
Thick PTFE*** Steel -10 °C (14 °F) 60 °C (140 °F)
-10 °C (14 °F) 180 °C (356 °F)
Thick PTFE*** Stainless steel -25 °C (-13 °F) 60 °C (140 °F)
-25 °C (-13 °F) 180 °C (356 °F)
40 °C (-40 °F)**
PFA*** Steel -10 °C (14 °F) 60 °C (140 °F)
-10 °C (14 °F) 180 °C (356 °F)
PFA*** Stainless steel -25 °C (-13 °F) 60 °C (140 °F)
-25 °C (-13 °F) 180 °C (356 °F)
40 °C (-40 °F)**
ETFE Steel -10 °C (14 °F) 60 °C (140 °F)
-10 °C (14 °F) 130 °C (266 °F)
ETFE Stainless steel -25 °C (-13 °F) 60 °C (140 °F)
-25 °C (-13 °F) 130 °C (266 °F)
40 °C (40 °F)**
* Only for China production site
** For (optional) low-temperature version only
*** Only for design level ‘A’