142 FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
… 13 Specification
… HygienicMaster – Material load for process connections
Flange devices
G10215
0
5
10
15
20
25
30
35
40
45
-30 -10 10 30 50 70 90 110 130 150 170 190 [°C]
-22 14 50 86 122 158 194 230 266 302 338 374 [°F]
0
72.5
145.0
217.5
290.0
362.5
435.0
507.5
580.0
652.5
PN 40
PN 25
PN 16
PN 10
T
medium
P
medium
[bar]
P
medium
[psi]
Figure 91: DIN flange, stainless steel, up to DN 100 (4 in)
G10216
CL 300
CL 150
0
5
10
15
20
25
30
35
40
45
50
55
-30 -10 10 30 50 70 90 110 130 150 170 190 [°C]
-22 14 50 86 122 158 194 230 266 302 338 374 [°F]
72.5
145.0
217.5
290.0
362.5
435.0
507.5
580.0
652.5
725.5
797.5
0
T
medium
P
medium
[bar]
P
medium
[psi]
Figure 92: DIN flange, stainless steel, up to DN 100 (4 in) (CL 150 / 300)
JIS 10K-B2210 flange
DN Material PN T
medium
P
medium
DN 25 to 100
(1 to 4 in)
Stainless steel 10 25 to 130 °C
(13 to 266 °F)
10 bar (290 psi)
(145 psi)
Wafer type devices
G12040
0
5
10
15
20
25
30
35
40
45
-30
-22
-10
14
10
50
30
86
50
122
70
158
90
194
110
230
130
266
[°C]
[°F]
PN 40 /
300CL
PN 25
PN 16 /
Cl150
PN 10
T
medium
P
medium
[bar]
P
medium
[psi]
0
72.5
145
217.5
290
362.6
435
507.6
580
652.6
Figure 93: Wafer type design
JIS 10K-B2210 wafer type design
DN Material PN T
medium
P
medium
DN 32 to 100
(1 ¼ to 4 in)
1.4404
1.4435
1.4301
10 25 to 130 °C
(13 to 266 °F)
10 bar (290 psi)
(145 psi)
14 Additional documents
Note
An additional document with Ex safety instructions is
available for measuring systems that are used in potentially
explosive atmospheres.
Ex safety instructions are an integral part of this manual. As
a result, it is crucial that the installation guidelines and
connection values it lists are also observed.
The icon on the name plate indicates
the following:
Note
All documentation, declarations of conformity, and certificates
are available in ABB's download area.
www.abb.com/flow
Dimensions in the Datasheet
Trademarks
HART is a registered trademark of FieldComm Group, Austin, Texas, USA
Modbus is a registered trademark of the Modbus Organization
PROFIBUS and PROFIBUS DP are registered trademarks of PROFIBUS &
PROFINET International (PI)
LINATEX is a registered trademark of Linatex Ltd.
Hastelloy is a registered trademark of Haynes International, Inc.
Change from two to one column

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ProcessMaster FEP630 series and is the answer not in the manual?

ABB ProcessMaster FEP630 series Specifications

General IconGeneral
BrandABB
ModelProcessMaster FEP630 series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals