EasyManuals Logo

ABB ProcessMaster FEP630 series User Manual

ABB ProcessMaster FEP630 series
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #95 background imageLoading...
Page #95 background image
FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D 95
Menu: Communication
Menu / parameter Description
Communication
...HART Selection of submenu ‘...HART’ using .
...Modbus Selection of submenu ‘...Modbus’ using .
...Profibus Selection of submenu ‘...Profibus’ using .
Communication / ...HART
Device Address Selection of HART device address.
Note
The HART protocol has provisions for creating a bus with up to 15 devices (1 to 15)).
If an address greater than 0 is set, the device operates in multidrop mode. The current output 31 / 32 / Uco is fixed to 4 mA.
HART communication takes place only through current output 31 / 32 / Uco.
Loop Current Mode Selection of the operating mode for current output with HART communication.
• Multidrop Fixed
• Normal Signaling
HART Tag Entry of a HART TAG number as unique identifier for the device.
Alphanumeric, a maximum of 8 characters, upper case only, no special characters.
HART Long Tag Entry of a HART TAG number as unique identifier for the device.
Alphanumeric, maximum of 32 characters, ASCII
Only starting from HART version 7!
HART Descriptor Entry of a HART descriptor.
Alphanumeric, a maximum of 16 characters, upper case only, no special characters.
HART Message Display of the alphanumeric TAG number.
HART Manuf. ID Display of the HART manufacturer ID. ABB = 26
HART Device ID Display of the HART device ID.
HART Find Select whether the transmitter must respond to the HART command 73 (Find Device).
Off: The transmitter does not respond to command 73.
Once: The transmitter responds once to command 73.
Continuous: The transmitter always responds to command 73.
Last HART Command Display of the most recently sent HART command.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ProcessMaster FEP630 series and is the answer not in the manual?

ABB ProcessMaster FEP630 series Specifications

General IconGeneral
BrandABB
ModelProcessMaster FEP630 series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals