3.11 Special safety instructions (UL portfolio)
3.11.1 Important safety instructions (UL portfolio)
Warning: Obey the basic precautions for electric products, including the
instructions in this section.
Caution: To reduce the risk of fire, connect this EVSE only to a circuit
provided with 40 A maximum branch circuit overcurrent protection in
accordance with the National Electrical Code, ANSI/NFPA 70.
Read all the instructions befor you use this EVSE.
Make sure that adults supervise this EVSE is when it is used around children.
Do not put fingers into the EV connector.
Do not use this product if the flexible power cord or EV charge cable is frayed,
has broken insulation, or any other signs of damage.
Do not use this EVSE if the enclosure or the EV connector is broken, cracked,
open, or shows any other indication of damage.
Install an insulated grounding conductor that is identical in size, insulation
material, and thickness to the grounded and ungrounded branch-circuit supply
conductors, except that it is green with or without one or more yellow stripes,
as part of the branch circuit that supplies the EVSE.
Connect the grounding connector of the previous bullet point to earth at the
EVSE or, when supplied by a separately derived system, at the supply
transformer.
Closing requirements
1.
SAVE THESE INSTRUCTIONS