47
PARAMETER MENU CONT’D
PARAM.
PARAM.PARAM.
PARAM. PARAMETER
PARAMETERPARAMETER
PARAMETER RANGE OF
RANGE OFRANGE OF
RANGE OF FACTORY
FACTORYFACTORY
FACTORY
NUMBER
NUMBERNUMBER
NUMBER NAME
NAMENAME
NAME ADJUSTMENT
ADJUSTMENTADJUSTMENT
ADJUSTMENT DEFAULT
DEFAULTDEFAULT
DEFAULT
21 SLIP CMP .0 - 5.0 % .0 %
22 TORQUE CONSTANT, VARIABLE, CONSTANT
CT / NOCMP
23 CARRIER 2.5, 6, 8, 10, 12, 14 kHz 2.5 kHz
25 START NORMAL, POWER-UP, NORMAL
AUTO RE-, RE-BRAKE
26 STOP RAMP, COAST COAST
27 ROTATION FORWARD, REVERSE, FORWARD
FWD&REV, FWD@LOC
28 AUTO/MAN AUTO, MANUAL, BOTH BOTH
29 MANUAL KEYPAD, 0-10 VDC KEYPAD
30 CONTROL LOCAL, REMOTE, BOTH LOCAL
31 HZ UNITS HERTZ, RPM, % HZ, HERTZ
/SEC, /MIN, /HR, NONE
32 HZ MULT .10 - 650.0 1.00
33 SPEED DP XXXXX, XXX.X, XX.XX, XXXXX
X.XXX, .XXXX
34 LOAD MLT 95 - 139 % 100%
35 CONTRAST LOW, MED, HIGH HIGH
39 TB5 MIN .00 - 360.0 Hz (NOTE 2) .00 Hz
40 TB5 MAX .00 - 360.0 Hz (NOTE 2) 60.00 Hz
42 TB10A OUT NONE, 0-10V, 2-10V NONE
43 @TB10A 3.00 - 360.0 HZ (NOTE 2) 60.00 Hz
44 TB10B OUT NONE, 0-10V, 2-10V NONE
45 @TB10B 10 - 200 % 125%
NOTE 2: MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE.