71
NOTE 1: The factory default value is 0019.
NOTE 2: If PASSWORD is set to 0000, the function is disabled. Pressing the
PROG/RUN key will result in direct entry into the PROGRAM mode without
having to enter a password.
63 SOFTWARE (SOFTWARE VERSION)
This parameter displays the software code and revision number of the control
board software. This information is useful when contacting the factory for
programming or troubleshooting assistance. This is a “view-only” parameter, and
cannot be changed.
64 MONITOR (MONITOR MODE)
This parameter is used to enable (ON) or disable (OFF) the MONITOR MODE
function. The functionality is explained below:
ON Pressing the PROG/RUN key will call up the PASSWORD
prompt. If the ENTER key is pressed while the password
value reads 0000, the MONITOR MODE is entered and
parameters can be viewed (except for PASSWORD), but not
changed.
OFF Pressing the PROG/RUN key will call up the PASSWORD
prompt. If the ENTER key is pressed while the password
value reads 0000 (or any other incorrect value), it will be
treated as in incorrect password and the display will flash
ERROR: INCORRECT, and then return to the PASSWORD
prompt to allow another attempt at entering the correct
password.
65 PROGRAM (PROGRAM FACTORY DEFAULTS)
WARNING!
STOP (TB-1) and EXTERNAL FAULT (TB-13D) circuitry may be disabled if
parameters are reset to factory defaults! The drive must be reprogrammed after a
RESET in order to insure proper operation.
FAILURE TO DO SO MAY RESULT IN DAMAGE TO EQUIPMENT AND/
OR INJURY TO PERSONNEL!