Page 49
Command Name Hex Command PEQ-1 Commands
Enable PEQ FF, 03, 00, 15, 40, 58, FF Turns on the Parametric Equalizer Function
Disable PEQ FF, 03, 00, 15, 41, 59, FF Turns off the Parametric Equalizer Function
Get State FF, 03, 00, 15, 43, 5B, FF Requests the current status of the Parametric Equalizer Function
Set Preset 1 FF, 03, 00, 15, 4C, 64, FF Stores the current PEQ Setting as Preset 1
Recalls Preset 1 FF, 03, 00, 15, 48, 60, FF Recalls the current PEQ Setting for Preset 1
Set Preset 2 FF, 03, 00, 15, 4D, 65, FF Stores the current PEQ Setting as Preset 2
Recalls Preset 2 FF, 03, 00, 15, 49, 61, FF Recalls the current PEQ Setting for Preset 2
Set Preset 3 FF, 03, 00, 15, 4E, 66, FF Stores the current PEQ Setting as Preset 3
Recalls Preset 3 FF, 03, 00, 15, 4A, 62, FF Recalls the current PEQ Setting for Preset 3
Set Preset 4 FF, 03, 00, 15, 4F, 67, FF Stores the current PEQ Setting as Preset 4
Recalls Preset 4 FF, 03, 00, 15, 4B, 63, FF Recalls the current PEQ Setting for Preset 4