16 80-0180-307, Rev A
Figure 23
SETTING UP AND USING THE eFORCE 150
General Information
The eForce 150 has the following features and requirements:
A keypad (with numbers 0-9, *, and #) that is used for
programming. In normal operating mode, the * key is used as
the ENTER key after user code entry.
Each key press flashes the yellow LED and sounds one tone.
Audible and visual keypad feedback can be disabled (see
programming instructions).
Master and Emergency Codes must be reprogrammed from the
factory pre-set codes before user codes may be entered. The
factory preset Master and Emergency codes (1234 & 4321)
cannot be revised back into the unit.
All codes need to be entered twice for validation during
programming. If the two entered codes do not match, the eForce
150 will exit programming mode and the previous code will
remain active.
Following a number of 5 successive invalid code entries, the red
LED flashes once and a tone indicates that the eForce 150 will
no longer accept further entries for 15 seconds. One tone per
second sounds during this time. Refer to programming
instruction to change default settings for successive invalid code
entries and error lockout time.