37 80-0180-307, Rev A
15. REMOVE the Allen key.
16. TURN key into the neutral position and REMOVE key from the
cylinder.
17. ENTER a known user code to ensure the eForce 150 is functioning
correctly.
18. REFER to Troubleshooting section if eForce 150 does not function
properly.
TROUBLESHOOTING
Green light comes on, but lever will not retract latch-bolt.
1. CHECK the eForce 150 body connection with lock/latch mechanism.
2. CHECK the cylinder tailpiece length (see installation instructions).
3. CHECK for proper door preparation (refer to door templates).
No lights come on when pushbuttons are depressed.
1. ENSURE Visual Keypad Feedback is set to Enable (PCC32).
2. CHECK battery installation.
3. CHECK 6-Volt battery.
4. CHECK keypad terminal connection.
No tones sound when pushbuttons are depressed.
1. ENSURE Audible Keypad Feedback is set to Enable (PCC 31).
2. CHECK battery installation.
3. CHECK 6-Volt battery.
4. CHECK keypad terminal connection.
Factory default codes not working.
1. DELETE all users and REPROGRAM default codes.
User codes not working.
1. ENSURE Lockout Code has not been entered.
2. CHECK battery power (operator may be in blackout mode). SEE
“Replacing the eForce 150 Batteries” section.
3. CHECK eForce 150 body connection.
Operator stays unlocked.
1. ENSURE Passage Code has not been entered.
2. CHECK cylinder tailpiece length (see installation instructions).
3. CHECK eForce 150 body connection.