24 80-0180-307, Rev A
Passage Code
1. PERFORM the following to program the Passage Code (Location 5).
NOTE: Yellow LED will blink continuously during programming.
a. PRESS and HOLD # for approximately 5 seconds, and
RELEASE when the yellow LED blinks.
NOTE: After Step b, there will be green LED flash and 2 short
tones.
b. ENTER Master Code or Supervisor Code and then #.
NOTE: After Step c, there will be green LED flash and 2 short
tones.
c. ENTER 51#
NOTE: After Step d, there will be green LED flash and 2 short
tones.
d. ENTER 5#
NOTE 1: Passage Code must be 4–7 digits.
NOTE 2: After Step e, there will be green LED flash and 2 short
tones.
e. ENTER new Passage Code and then #.
NOTE: After Step f, there will be green LED flash and 2 short
tones to indicate successful Supervisor Code
programming.
f. RE-ENTER new Passage Code and then #.
2. PRESS # within 2 seconds to stay in programming mode, and then
ENTER 51# to continue programming.
Normal User Codes
1. PERFORM the following to program the Normal User Codes
(Locations 6–150).
NOTE: Yellow LED will blink continuously during programming.
a. PRESS and HOLD # for approximately 5 seconds, and
RELEASE when the yellow LED blinks.
NOTE: After Step b, there will be green LED flash and 2 short
tones.
b. ENTER Master Code or Supervisor Code and then #.