19 80-0180-307, Rev A
Normal User Codes. Normal User codes are used to briefly
unlock the device. A correct code entry is indicated by a green
LED flashing once per second. An incorrect code entry is
indicated by red LED flash and 3 tones. Up to 144 different
Normal User codes may be programmed. These codes may not
be programmed until after the default Master and Emergency
codes have been reprogrammed. They must be between 2 and
7 digits.
One-Time User Codes. One-Time user codes are used to
unlock the device and are only valid for a single operation of the
eForce 150. A correct code entry is indicated by a green LED
flashing once per second. An incorrect code entry is indicated
by red LED flash and 3 tones. Different One-Time user codes
may be programmed into locations 151 and 152. These codes
may not be programmed until after the default Master and
Emergency codes have been reprogrammed. They must be
between 2 and 7 digits. After a One-Time user code is used to
operate the eForce 150, the same or a new code must be
programmed into the eForce 150 using the Master or Supervisor
codes.
Features and Options Descriptions
NOTE: Program Command Codes (PCC) are designated codes for
programming and are always entered after the Master or
Supervisor code during programming mode.
The following are the eForce 150 features and options:
Error Lockout. The eForce 150 will stop accepting key presses
after 3 successive invalid entries. Error Lockout is indicated by
one red LED flash and 3 tones, followed by one tone per second
for the duration of the Lockout time. The eForce 150 will not
accept any key presses during this preset (PCC 34) time. The
Error Lockout function overrides the horn disable
function (PCC 31).
Low Battery Indicator. When the battery voltage drops below
4.0 volts, the eForce 150 will emit 4 tones before allowing entry.
If the battery voltage drops below 3.8 volts, the eForce 150 will
enter blackout mode, indicated by 4 tones followed by 4 tones,
and will not open. The eForce 150 will function for the Master,
Emergency, and Supervisor codes only.
Piezo Sounder. This will emit a tone with each keystroke and
varying tones to indicate various conditions. The sounder can be
disabled using the Master or Supervisor code (PCC31).