17 80-0180-307, Rev A
Programming Information
1. PERFORM the following to enter the programming mode.
a. PRESS and HOLD the # key until the yellow LED flashes three
times.
b. RELEASE the # key and the yellow LED will begin to flash
continually.
NOTE: At the end of each programming step ending with the #
key (ENTER), the green LED will flash twice and the
sounder will emit 2 tones to indicate that valid values were
accepted.
c. PROGRAM, as required.
d. WHEN the end of the programming sequence is reached,
THEN WAIT two (2) seconds for the device to time out and
return to normal operating mode,
OR PRESS the * key to exit programming mode.
Speed Mode
1. PERFORM the following to enter the speed mode.
NOTE: The following step initiates the “speed programming
mode,” eliminating the need to re-enter the Master or
Supervisor code.
a. At the end of a programming sequence, PRESS the # key within
2–4 seconds to program additional codes.
NOTE: For the following steps, the red LED will flash and a tone
will indicate that the programming mode has been exited.
b. In programming mode, PRESS the * key at any time to exit this
mode.
c. WAIT 2 seconds before entering any code.
NOTE 1: The programming mode will exit automatically if an invalid
code is entered during programming (indicated by a red
LED flash and a tone).
NOTE 2: The eForce 150 will always return to the standard user
mode after the programming mode is exited.
d. IF the programming mode has exited,
THEN PRESS the # key to reinitiate the programming mode.