EasyManuals Logo
Home>Agilent Technologies>Measuring Instruments>8562EC

Agilent Technologies 8562EC User Manual

Agilent Technologies 8562EC
716 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #383 background imageLoading...
Page #383 background image
Chapter 7 383
Language Reference
ACPBRWID Adjacent Channel Power Burst Width
ACPBRWID Adjacent Channel Power Burst
Width
Syntax
Figure 7-12 ACPBRWID Syntax
Description
The ACPBRWID command sets the on-time (pulse width) of the burst
RF signal. The pulse width is needed to set the gating times when using
the gated method for adjacent channel power measurements.
Parameters
number 5 µs to 9.5 seconds
Query Response
Figure 7-13 ACPBRWID Query Response
Example
10 REAL Burstwidth
20 Burstwidth = 6.53
30 OUTPUT 718;"ACPBRWID";Burstwidth;"MS;";

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8562EC and is the answer not in the manual?

Agilent Technologies 8562EC Specifications

General IconGeneral
BrandAgilent Technologies
Model8562EC
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals