Chapter 7 463
Language Reference
EXTMXR External Mixer Mode
EXTMXR External Mixer Mode
Syntax
Figure 7-105 EXTMXR Syntax
Description
The EXTMXR command specifies the external mixing mode as either
preselected (PRE) or unpreselected (UNPR). This command applies
only to the selection of the type of external mixer to be used. It does not
switch the analyzer from internal to external mixing. This command is
not available for use with an Agilent 8560E/EC Option 002.
Query Response
Figure 7-106 EXTMXR Query Response
Example
10 OUTPUT 718;"EXTMXR PRE;"
20 END