Chapter 4 Remote Interface Reference
The SCPI Status Registers
94
The Standard Event register is cleared when:
You execute the
*CLS
(clear status) command.
You query the event register using the
*ESR?
(Even t Status regi s ter)
command.
For example, 28 (4 + 8 + 16) is returned when you have queried the status of
the Standard Event register, QYE, DDE, and EXE conditio ns have occurred.
The Standard Event Enable register is cleared when:
You execute the
*ESE 0
command.
You turn on the power and have previously configured the power supply
using the
*PSC 1
comm and.
The enable register will not be cleared at power-on if you have previously
configured the power supply using the
*PSC 0
command.
The Status Byte Register
The Status Byte summary register reports conditions from the other status
registers. Query data that is waiting in the power supply’s output buffer is
immediately reported through the “Message Available” bit (bit 4) of Status Byte
register. Bits in the summary register are not latched. Clearing an event register
will clear the corresponding bits in t he Stat us Byte summary register . Reading
all messages in the output buffer , including any pending queries, will clear the
message available bit.
Table 4-5. Bit Definitions – Status Byte Summary Register
Bit Decimal
Value
Definition
0-2 Not Used 0 Always set to 0.
3 QUES
8
One or more bits are set in the questionable status
register (bits must be “enabled” in the enable register).
4 MAV 16 Data is available in the power supply output buffer.
5 ESB
32
One or more bits are set in the standard event register
(bits must be “enabled” in the enable register).
6 RQS 64 The power supply is requesting service (serial poll).
7 Not Used 0 Always set to 0.

Table of Contents

Other manuals for Agilent Technologies E3633A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E3633A and is the answer not in the manual?

Agilent Technologies E3633A Specifications

General IconGeneral
BrandAgilent Technologies
ModelE3633A
CategoryPower Supply
LanguageEnglish

Related product manuals