EasyManua.ls Logo

Agilent Technologies E3633A - Page 129

Agilent Technologies E3633A
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Error Messages
Execution Errors
117
5
-430 Query DEADLOCKED
A command was received which generates too much data to fit in the output
buffer and the input buffer is also full. Command execution continues but all
data is lost.
-440 Query UNT E RMIN ATED af ter indefinite response
The
*IDN?
command m ust be the l ast query comm and withi n a command
string.
Exampl e:
*IDN?;:SYST:VERS?
501 Isolator UART framing error
502 Isolator UART overrun error
511 RS-232 framing error
512 RS-232 overrun error
513 RS-232 parity error
514 Command allowed only with RS-232
There are three commands which are only allowed with the RS-232 interface:
SYSTem:LOCal
,
SYSTem
:
REMote
, and
SYSTem:RWLock
.
521 Input buffer overflow
522 Output buffer overflow
550 Command not allowed in local
You should alw ays execute the
SYSTem:REMote
comman d before sending
other commands over the RS-232 interface.

Table of Contents

Other manuals for Agilent Technologies E3633A

Related product manuals