A05 Admin Guide
AKUVOX SMART INTERCOM www.akuvox.com
will be reversed an vice versa.
Wiegand Output Data Order: set the Wiegand output data sequence
between Normal and Reversed if you select Reversed then the input card
number will be reversed an vice versa.
Wiegand Output CRC: tick to enable the parity check function to ensure
that signal-based data can be transmitted correctly according to the
established data transmission format.
17.2. Integration via RS485
RS485 integration mode should be configured properly on the access control
terminal’s web interface before you can implement the integration between
the access control terminal and the third-party devices. To configure the
configuration on web Device > RS485 > RS485 List interface.
Parameter Set-up:
RS485 List: select integration mode between two options: None, OSDP,
the detail for the two options will be provided in the following chart.
If you select None then the RS485 integration
will be disabled.
If you Select OSDP Mode, then the
integration communication between the A05
series access control terminal and the
third-party device is via OSDP protocol. You
are required to check for the device
integration protocol and make sure if that
they use the same integration protocol.