Sample Output
*A:MTU-A# show chassis
===============================================================================
Chassis Information
===============================================================================
Name : MTU-A
Type : 7210 SAS-M-1
Location :
Coordinates :
CLLI code :
Number of slots : 2
Number of ports : 24
Critical LED state : Off
Major LED state : Off
Minor LED state : Off
Over Temperature state : OK
Base MAC address : 00:11:00:22:bc:11
Hardware Data
Part number :
CLEI code :
Serial number : MTUSN107210
Manufacture date :
Manufacturing string :
Manufacturing deviations :
Time of last boot : 2001/06/27 11:14:43
Current alarm state : alarm cleared
-------------------------------------------------------------------------------
Environment Information
Number of fan trays : 1
Number of fans : 3
Power supply
number
The ID for each power supply installed in the chassis.
AC power
Within range — AC voltage is within range.
Out of range — AC voltage is out of range.
DC power
Within range — DC voltage is within range.
Out of range — DC voltage is out of range.
Over temp
Within range — The current temperature is within the acceptable
range.
Out of range — The current temperature is above the acceptable
range.
Status
Up — The specified power supply is up.
Down — The specified power supply is down
Label Description (Continued)