Interface Configuration
7210 SAS M, T, X, R6, R12, Mxp Interface Configuration Guide Page 231
Sample Output
*A:MTU-A# show card A detail
===============================================================================
Card A
===============================================================================
Slot Provisioned Equipped Admin Operational
Card-type Card-type State State
-------------------------------------------------------------------------------
A sfm-24g sfm-24g up up/active
BOF last modified : N/A
Config file version : WED JUN 27 11:12:21 2008 UTC
Config file last modified : 2008/06/27 11:42:06
Config file last saved : N/A
M/S clocking ref state : primary
Part number The SF/CPM part number.
CLEI code The code used to identify the router.
Serial number The SF/CPM part number. Not user modifiable.
Manufacture date The chassis manufacture date. Not user modifiable.
Manufacturing
string
Factory-inputted manufacturing text string. Not user modifiable.
Administrative
state
Up — The card is administratively up.
Down — The card is administratively down.
Operational
state
Up — The card is operationally up.
Down — The card is operationally down.
Time of last
boot
The date and time the most recent boot occurred.
Current alarm
state
Displays the alarm conditions for the specific board.
Status Displays the current status.
Temperature Internal chassis temperature.
Temperature
threshold
The value above which the internal temperature must rise in order to
indicate that the temperature is critical.
Software boot
version
The version of the boot image.
Memory capacity The total amount of memory.
Label Description (Continued)