EasyManua.ls Logo

Alcatel-Lucent 7705 - Page 131

Alcatel-Lucent 7705
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7705 SAR Interfaces
7705 SAR OS Interface Configuration Guide Page 131
Table 6: Show Card Detailed Output Fields
Label Description
Clock source The system’s clock source
Available MDA slots The number of card slots available
Installed MDAs The number of cards installed
Part number The chassis part number
CLEI code The Common Language Equipment Identifier (CLEI) code string
for the router
Serial number The chassis serial number
Manufacture date The chassis manufacture date
Manufacturing
string
Factory-inputted manufacturing text string
Manufacturing
deviations
A record of changes done to the hardware or software that is
outside the normal revision control process
Administrative
state
Up — the card is administratively up
Down — the card is administratively down
Operational State Up — the card is operationally up
Down — the card is operationally down
Provisioned — there is no card in the slot but it has been
preconfigured
Failed — the provisioned card has operationally failed
Temperature Internal chassis temperature
Temperature
threshold
The value above which the internal temperature must rise in order
to indicate that the temperature is critical
Software boot (rom)
version
The version of the boot rom image
Software boot
version
The version of the boot image
Software version The software version number
Time of last boot The date and time the most recent boot occurred
Current alarm state The alarm conditions for the adapter card

Table of Contents

Other manuals for Alcatel-Lucent 7705