7705 SAR Interfaces
7705 SAR OS Interface Configuration Guide Page 161
J0 String The section trace value that is sent to the far-end port
Section Trace
Mode
byte — the section trace in the SONET section header is set in bytes
string — a text string is used to identify the SONET section header
increment-z0 — an incremental STM ID is configured instead of
a static value
Rx S1 Byte The value of the received SONET/SDH S1 byte
Rx K1/K2 Byte The value of the received SONET/SDH K1/K2 byte
Rx J0 String
(Hex)
The hex value of the received J0
Cfg Alarm The type of alarms to be logged and reported for the SONET/SDH port
Alarm Status The current alarm state
BER SD Threshold The configured threshold for line signal degradation BER error rate,
that when crossed determines the signal degradation and signal failure
BER SF Threshold The configured threshold for line signal failure BER error rate, that
when crossed determines the signal degradation and signal failure
Hold time up The hold-timer value for link-up event dampening
Hold time down The hold-timer value for link-down event dampening
Sonet Section SONET section statistics
ES-S The number of Errored Seconds errors
SES-S The number of Severely Errored Seconds errors
SEFS-S The number of Severely Errored Framing Seconds errors
CV-S The number of Code Violations errors
LOS The number of Loss of Signal errors
LOC The number of Loss of Clock errors
LOF The number of Loss of Frame errors
OOF The number of Out of Frame errors
B1 Error The number of B1 errors
Table 16: Show Port Detail Output Fields (SONET/SDH Port) (Continued)
Label Description