Interface Configuration
7750 SR Interface Configuration Guide Page 407
info-notification
Syntax info-notification
Context config>port>ethernet>efm-oam>link-monitoring>local-sf-action
Description The context allows the operator to set different flags in the Information OAM PDU. The flags can be used to
notify the peer that a local signal failure threshold has been exceeded within the configured window. This is
useful when the local node supports the link monitoring function, but the remote peer does not support this
capability. Information OAM PDUs are sent on the interval where the Event Notification OAM PDU is typ-
ically only sent on the initial sf-threshold crossing event. It is strongly suggested one of the Information
OAMPDU Flag fields used to continually communicate current monitor state to the peer.
Interactions: The signal failure threshold will trigger these actions.
dying-gasp
Syntax [no] dying-gasp
Context config>port>ethernet>efm-oam>link-monitoring>local-sf-action>info-notification
Description The configuration option will set the dying gasp Flag field in the Information OAMPDU when the local sig-
nal failure (sf-threshold) threshold is reached. This will be maintained in all subsequent Information OAMP-
DUs until the situation is cleared.
Interactions: The signal failure threshold will trigger these actions.
Default no dying-gasp
critical-event
Syntax [no] critical-event
Context config>port>ethernet>efm-oam>link-monitoring>local-sf-action>info-notification
Description The configuration option will set the critical event Flag field in the Information OAMPDU when the local
signal failure (sf-threshold) threshold is reached. This will be maintained in all subsequent Information
OAMPDUs until the situation is cleared.
Interactions: The signal failure threshold will trigger these actions.
Default no critical-event