3 Maintain the ATCA Subrack
9. Open a telnet session on shelf manager, using Putty application:
Launch putty.exe
A ’PuTTY Configuration’ window is open.
In the ’Protocol’ area select <Telnet>
Complete the ’Host Name (op IP address)’ field with 172.t.y.x
where:
t is 17 if the replaced JBXSSW is JBXSSW2
t is 18 if the replaced JBXSSW is JBXSSW1
x is 8 if the replaced JBXSSW is JBXSSW2
x is 9 if the replaced JBXSSW is JBXSSW1
y is 3 for ATCA shelf 3
y is 4 fot ATCA shelf 4.
Click on [ Open ] to start session.
10. Enter the user name and password:
Username:
root
Password:
root
11. Check the SMM status:
sv_status
If the SMM is the active one continue with the next steps.
If the SMM is the standby one, activate it using the following command:
sv_activate
and continue with the next steps.
12. On the active SMM enter:
cd /usr/bin
13. To synchronize the boards:
If the shelf ID is 3, enter:
./hpishaddr -e “{RACK,0}{ADVANCEDTCA_CHASSIS,3}“
If the shelf ID is 4, enter:
./hpishaddr -e “{RACK,0}{ADVANCEDTCA_CHASSIS,4}“
14. Close the connection on the shelf manager.
15. Open a telnet session on the active JBXOMCP
# telnet 172.t.y.x
where:
t is 17 if the replaced JBXSSW is JBXSSW2
t is 18 if the replaced JBXSSW is JBXSSW1
y is 3 for ATCA shelf 3
y is 4 for ATCA shelf 4